Home > Products > Valve > Control Valve > D3 High Pressure Straight Control Valve – Fisher

D3 High Pressure Straight Control Valve – Fisher

D3 High Pressure Straight Control Valve – Fisher is a compact, robust valve designed for on-off control. This valve is suitable for use as a dump valve for gas separator and scrubber. It is also suitable for other high pressure applications in natural gas production, compression and processing. D3FLOPRO is easy to maintain.Remove the patented deep hole hammer nut and lift the actuator/bonnet assembly from the valve to maintain the trim and packing without removing the actuator. D3 High Pressure Straight Control Valve – Fisher are supplied with sizes NPS 1 and 2, pressure class CL900, NPT end connections and NPS 2, pressure class CL600, convex flange end connections.

Product Features:
D3 High Pressure Straight Control Valve – Fisher is a compact, robust valve designed for on-off control. This valve is suitable for use as a dump valve for gas separator and scrubber. It is also suitable for other high pressure applications in natural gas production, compression and processing. D3FLOPRO is easy to maintain. Remove the patented deep hole hammer nut and lift the actuator/bonnet assembly from the valve to maintain the trim and packing without removing the actuator. D3 High Pressure Straight Control Valve – Fisher are supplied with sizes NPS 1 and 2, pressure class CL900, NPT end connections and NPS 2, pressure class CL600, convex flange end connections.

d3 high pressure straight control valve fisher6

D3 High Pressure Straight Control Valve – Fisher have following features:
Safer bonnet/body connection – the unique design provides additional protection if you accidentally start removing the bonnet/body connection while there is still pressure in the body. After removing the hammer nut, the pin mounted on the bonnet helps to ensure that the bonnet is removed from the body while the threads remain engaged. This helps to relieve internal pressure while keeping the actuator in the body.
Field selectable flow rate — The FLOPRO adjusts flow capacity without changing the trim. As a result, multiple flow requirements can be met with a single set of trims, reducing inventory and maintenance costs.
Two End Connections – D3 High Pressure Straight Control Valve – Fisher design offers CL900 threaded end construction and CL600 RF flange construction.
Dynamic load packing system — packing system improves stem seal and helps prevent valuable or harmful process fluid or gas leakage.It uses Enviro-Seal ™ packing technology to reduce packing maintenance requirements and provide superior emissions control.

Product Parameters:

Model Fisher D3
VALVE BODY SIZE MAXIMUM INLET
PRESSURE
TEMPERATURE RANGE
bar (psig)
NPS 1 NPT 155(2250) -46 to 93 (-50 to 200)
CL900 150(2185) 93 to 149(200 to 300)
NPS 2 NPT 155(2250) -46 to 93 (-50 to 200)
CL900 150(2185) 93 to 149(200 to 300)
NPS 1 NPT 103(1500) -46 to 93 (-50 to 200)
CL600 100(1455) 93 to 149(200 to 300)
NPS 2 NPT 103(1500) -46 to 93 (-50 to 200)
CL600 100(1455) 93 to 149(200 to 300)

Application and After-Sales Service:

Application of D3 High Pressure Straight Control Valve – Fisher
1. Coal gasification project
2. Clean energy gasification unit
3. Electricity
4. Hydrocarbons
5. Chemicals
6.Pulp and paper

After-sales service

Online support and Video technical support.

Inquiry:

*
*
Please Choose:
*
Hot Product
Name * E-mail *
Tel Country Message *
x